Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Table No. 1

Sample No. Heating Time Cooling Air Applied Max Pull Pressure Ends Closed
copyright Fast Fusion LLC - www.fast-fusion.com`
1 100 sec. No 7092 lbs 150 sec. No
2 100 sec. Yes 6856 lbs 210 sec. No
3 100 sec. Yes no pull No
4 100 sec. Yes 7092 lbs after 210 sec. Yes
5 100 sec. No 5910 lbs after 210 psi Yes
6 100 sec. Yes no pull Yes
7 100 sec. Yes 7092 lbs after 105 sec. Yes
8 100 sec. Yes 7092 lbs after 105 sec. Yes

entire contents copyright Fast Fusion - all rights reserved